<  Back to the Polytechnique Montréal portal

Items where Author is "Beaudoin, Gilles"

Up a level
Export as [feed] Atom [feed] RSS 1.0 [feed] RSS 2.0
Group by: Authors | Publication Date | Document subtype | No Grouping
Jump to: 2015 | 2014 | 2012 | 2011 | 2010 | 2009 | 2008 | 2007 | 2006 | 2005 | 2004 | 2003
Number of items: 24.

2015

Lalande, V., Gosselin, F., Vonthron, M., Conan, B., Tremblay, C., Beaudoin, G., Soulez, G., & Martel, S. (2015). In vivo demonstration of magnetic guidewire steerability in a MRI system with additional gradient coils. Medical Physics, 42(2), 969-969. External link

Martel, S., Mathieu, J.-B., Felfoul, O., & Beaudoin, G. (2015). MR-tracking based on magnetic signature selective excitation. (Patent no. US8948841). External link

2014

Grenier, R., Périé-Curnier, D., Gilbert, G., Beaudoin, G., & Curnier, D. (2014). Assessment of mechanical properties of muscles from multi-parametric magnetic resonance imaging. Journal of Biomedical Science and Engineering, 7(8), 593-603. Available

Pouponneau, P., Soulez, G., Beaudoin, G., Leroux, J.-C., & Martel, S. (2014). MR Imaging of Therapeutic Magnetic Microcarriers Guided by Magnetic Resonance Navigation for Targeted Liver Chemoembolization. Cardiovascular and Interventional Radiology, 37(3), 784-790. External link

2012

Recuerda, M., Périé-Curnier, D., Gilbert, G., & Beaudoin, G. (2012). Assessment of mechanical properties of isolated bovine intervertebral discs from multi-parametric magnetic resonance imaging. BMC Musculoskeletal Disorders, 13(1). Available

2011

Gendron, D., Goussard, Y., Hamelin, B., Dussault, J.-P., Beaudoin, G., Cloutier, G., Chartrand-Lefebvre, C., Hadjadj, S., & Soulez, G. (2011, July). 3D iterative helical targeted CT. Application to contrast-enhanced vascular imaging [Paper]. 11th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, Potsdam, Germany. External link

Martel, S., Mathieu, J.-B., Yahia, L., Soulez, G., & Beaudoin, G. (2011). Method and system for propelling and controlling displacement of a microrobot in a blood vessel. (Patent no. US7962194). External link

2010

Olamaei, N., Cheriet, F., Beaudoin, G., & Martel, S. (2010, August). MRI visualization of a single 15 µm navigable imaging agent and future microrobot [Paper]. 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2010), Buenos Aires, Argentina. External link

2009

Piché, M., Cohen-Adad, J., Nejad, M. K., Perlbarg, V., Xie, G., Beaudoin, G., Benali, H., & Rainville, P. (2009). Characterization of cardiac-related noise in fMRI of the cervical spinal cord. Magnetic Resonance Imaging, 27(3), 300-310. External link

2008

Chanu, A., Felfoul, O., Beaudoin, G., & Martel, S. (2008). Adapting the Clinical MRI Software Environment for Real-Time Navigation of an Endovascular Untethered Ferromagnetic Bead for Future Endovascular Interventions. Magnetic Resonance in Medicine, 59(6), 1287-1297. External link

Martel, S., Mathieu, J.-B., Felfoul, O., Chanu, A., Aboussouan, É., Tamaz, S., Pouponneau, P., Yahia, L., Beaudoin, G., Soulez, G., & Mankiewicz, M. (2008). A computer-assisted protocol for endovascular target interventionsusing a clinical mri system for controlling untethered microdevices andfuture nanorobots. Computer Aided Surgery, 13(6), 340-352. External link

Felfoul, O., Mathieu, J.-B., Beaudoin, G., & Martel, S. (2008). In vivo MR-tracking based on magnetic signature selective excitation. IEEE Transactions on Medical Imaging, 27(1), 28-35. External link

Hamelin, B., Goussard, Y., Gendron, D., Dussault, J.-P., Cloutier, G., Beaudoin, G., & Soulez, G. (2008, May). Iterative CT reconstruction of real data with metal artifact reduction [Paper]. IEEE International Symposium on Biomedical Imaging: From Macro to Nano (ISBI '08), Paris, France. External link

Gendron, D., Goussard, Y., Beaudoin, G., Soulez, G., & Cloutier, G. (2008, August). Reconstruction of real tomographic data using algebraic methods [Paper]. 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2008, Vancouver, BC, Canada. External link

2007

Martel, S., Mathieu, J.-B., Felfoul, O., Chanu, A., Aboussouan, É., Tamaz, S., Pouponneau, P., Beaudoin, G., Soulez, G., Yahia, L., & Mankiewicz, M. (2007). Automatic Navigation of an Untethered Device in the Artery of a Living Animal Using a Conventional Clinical Magnetic Resonance Imaging System. Applied Physics Letters, 90(11), 14105-14105. External link

Martel, S., Mathieu, J.-B., Felfoul, O., Chanu, A., Aboussouan, É., Tamaz, S., Pouponneau, P., Yahia, L., Beaudoin, G., Soulez, G., & Mankiewicz, M. (2007, October). Medical and technical protocol for automatic navigation of a wireless device in the carotid artery of a living swine using a standard clinical MRI system [Paper]. 10th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2007), Brisbane, Australia. External link

2006

Mathieu, J.-B., Beaudoin, G., & Martel, S. (2006). Method of propulsion of a ferromagnetic core in the cardiovascular system through magnetic gradients generated by an MRI system. IEEE Transactions on Biomedical Engineering, 53(2), 292-299. External link

Aboussouan, E., Felfoul, O., Mathieu, J.-B., Beaudoin, G., & Martel, S. (2006, May). Real-time projection based technique for tracking ferromagnetic devices [Poster]. ISMRM 14th Scientific Meeting & Exhibition, Seattle, Wash.. External link

2005

Mathieu, J.-B., Martel, S., Yahia, L., Soulez, G., & Beaudoin, G. (2005). Preliminary investigation of the feasibility of magnetic propulsion for future microdevices in blood vessels. Bio-Medical Materials and Engineering, 15(5), 367-374. External link

Chanu, A., Martel, S., & Beaudoin, G. (2006, January). Real-time Magnetic Resonance Gradient-based Propulsion of a Wireless Microdevice Using Pre-Acquired Roadmap and Dedicated Software Architecture [Paper]. 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Shanghai, China. External link

2004

Martel, S., Mathieu, J.-B., Felfoul, O., Macicior, H., Beaudoin, G., Soulez, G., & Yahia, L. (2004, September). Adapting MRI systems to propel and guide microdevices in the human blood circulatory system [Paper]. 26th Annual International Conference of the IEEE Engineering in Medecine and Biology Society (EMBC 2004), San Francisco. External link

Felfoul, O., Mathieu, J.-B., Martel, S., & Beaudoin, G. (2004, September). Micro-device's susceptibility difference based MRI positioning system, a preliminary investigation [Paper]. 26th Annual International Conference of the IEEE Engineering in Medecine and Biology Society (EMBC 2004), San Francisco. External link

2003

Mathieu, J.-B., Martel, S., Yahia, L., Soulez, G., & Beaudoin, G. (2003, September). MRI systems as a mean of propulsion for a microdevice in blood vessels [Paper]. 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2003), Cancun, Mexico. External link

Mathieu, J.-B., Martel, S., Yahia, L., Soulez, G., & Beaudoin, G. (2003, May). Preliminary Studies for Using Magnetic Resonance Imaging Systems as a Mean of Propulsion for Microrobots in Blood Vessels and Evaluation of Ferromagnetic Artefacts [Paper]. Canadian Conference on Electrical and Computer Engineering (CCECE 2003), Montréal, QC, Canada. External link

List generated on: Wed May 20 02:23:37 2026 EDT