Tiago Teixeira, Tarik Hafyane, Nikola Stikov, Cansu Akdeniz, Andreas Greiser and Matthias G. Friedrich
Article (2016)
Open Acess document in PolyPublie and at official publisher |
|
Open Access to the full text of this document Published Version Terms of Use: Creative Commons Attribution Download (819kB) |
Abstract
Background: T1 mapping based on cardiovascular magnetic resonance (CMR) is a novel approach using the magnetic relaxation T1 time as a quantitative marker for myocardial tissue composition. Various T1 mapping sequences are being used, with different strengths and weaknesses. Data comparing different sequences head to head however are sparse.Methods: We compared three T1 mapping sequences, ShMOLLI, MOLLI and SASHA in phantoms and in a mid-ventricular slice of 40 healthy individuals (mean age 59 +/- 7 years, 45 % male) with low (68 %) or moderate cardiovascular risk. We calculated global and segmental T1 in vivo through exponential curve fitting and subsequent parametric mapping. We also analyzed image quality and inter-observer reproducibility.Results: There was no association of T1 with cardiovascular risk groups. T1 however differed significantly depending on the sequence, with SASHA providing consistently higher mean values than ShMOLLI and MOLLI (1487 +/- 36 ms vs. 1174 +/- 37 ms and 1199 +/- 28 ms, respectively; p < 0.001). This difference between sequences was much smaller in phantom measurements. In patients, segmental values were lower in the anterior wall for all sequences. Image quality, in general good for the steady-state-free-precession readouts in all sequences, was lower for SASHA parametric maps. On multivariate regression analysis, a longer T1 measured by MOLLI was correlated with lower ejection fraction and female gender. Inter-observer variability as assessed by intra-class correlation coefficients was excellent for all sequences (ShMOLLI: 0.995; MOLLI: 0.991; SASHA: 0.961; all p < 0.001).Conclusion: In a cross-sectional population with low to moderate cardiovascular risk, we observed a variation in T1 mapping results between inversion-recovery vs. saturation-recovery sequences in vivo, which were less evident in phantom images, despite a small interobserver variability. Thus, physiological factors, most likely related to B1 inhomogeneities, and tissue-specific properties, like magnetization transfer, that impact T1 values in vivo, render phantom validation insufficient, and have to be further investigated for a better understanding of the clinical utility of different T1 mapping approaches.
Uncontrolled Keywords
Relaxometry; Native T1 mapping; SASHA; ShMOLLI; MOLLI
Subjects: | 1900 Biomedical engineering > 1900 Biomedical engineering |
---|---|
Department: | Department of Electrical Engineering |
Research Center: | Other |
Funders: | Canadian Alliance for Healthy Hearts and Minds, Canadian Partnership for Tomorrow Project, Canadian Foundation for Innovation, Fonds de recherche du Québec--Santé, Montreal Heart Institute Foundation |
PolyPublie URL: | https://publications.polymtl.ca/3505/ |
Journal Title: | Journal of Cardiovascular Magnetic Resonance (vol. 18, no. 1) |
Publisher: | BioMed Central |
DOI: | 10.1186/s12968-016-0286-6 |
Official URL: | https://doi.org/10.1186/s12968-016-0286-6 |
Date Deposited: | 17 Dec 2018 16:02 |
Last Modified: | 28 Sep 2024 03:34 |
Cite in APA 7: | Teixeira, T., Hafyane, T., Stikov, N., Akdeniz, C., Greiser, A., & Friedrich, M. G. (2016). Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T. Journal of Cardiovascular Magnetic Resonance, 18(1), 1-12. https://doi.org/10.1186/s12968-016-0286-6 |
---|---|
Statistics
Total downloads
Downloads per month in the last year
Origin of downloads
Dimensions