<  Retour au portail Polytechnique Montréal

Optical biosensor based on porous silicon and tamm plasmon polariton for detection of CagA Antigen of Helicobacter pylori

Guoguang Rong, Alexey V. Kavokin et Mohamad Sawan

Article de revue (2024)

Document en libre accès dans PolyPublie et chez l'éditeur officiel
[img]
Affichage préliminaire
Libre accès au plein texte de ce document
Version officielle de l'éditeur
Conditions d'utilisation: Creative Commons: Attribution (CC BY)
Télécharger (1MB)
Afficher le résumé
Cacher le résumé

Abstract

Helicobacter pylori (H. pylori) is a common pathogen with a high prevalence of infection in human populations. The diagnosis of H. pylori infection is critical for its treatment, eradication, and prognosis. Biosensors have been demonstrated to be powerful for the rapid onsite detection of pathogens, particularly for point-of-care test (POCT) scenarios. In this work, we propose a novel optical biosensor, based on nanomaterial porous silicon (PSi) and photonic surface state Tamm Plasmon Polariton (TPP), for the detection of cytotoxin-associated antigen A (CagA) of H. pylori bacterium. We fabricated the PSi TPP biosensor, analyzed its optical characteristics, and demonstrated through experiments, with the sensing of the CagA antigen, that the TPP biosensor has a sensitivity of 100 pm/(ng/mL), a limit of detection of 0.05 ng/mL, and specificity in terms of positive-to-negative ratio that is greater than six. From these performance factors, it can be concluded that the TPP biosensor can serve as an effective tool for the diagnosis of H. pylori infection, either in analytical labs or in POCT applications.

Mots clés

Département: Département de génie électrique
Organismes subventionnaires: Leading Innovative and Entrepreneur Team Introduction Program of Zhejiang, Westlake University (Hangzhou, China), Tencent Foundation, Zhejiang Key R&D Program
Numéro de subvention: 2020R01005, 10318A992001, XHTX202003001, 2021C03002
URL de PolyPublie: https://publications.polymtl.ca/65414/
Titre de la revue: Sensors (vol. 24, no 16)
Maison d'édition: MDPI
DOI: 10.3390/s24165153
URL officielle: https://doi.org/10.3390/s24165153
Date du dépôt: 07 mai 2025 16:00
Dernière modification: 26 nov. 2025 17:49
Citer en APA 7: Rong, G., Kavokin, A. V., & Sawan, M. (2024). Optical biosensor based on porous silicon and tamm plasmon polariton for detection of CagA Antigen of Helicobacter pylori. Sensors, 24(16), 5153 (13 pages). https://doi.org/10.3390/s24165153

Statistiques

Total des téléchargements à partir de PolyPublie

Téléchargements par année

Provenance des téléchargements

Dimensions

Actions réservées au personnel

Afficher document Afficher document