<  Retour au portail Polytechnique Montréal

A model-based continuous commissioning method for an efficient integration of ground source heat pumps in the building ecosystem

Giulio Tonellato, Michaël Kummert, José A. Candanedo, Gabrielle Beaudry et Philippe Pasquier

Article de revue (2025)

Document en libre accès dans PolyPublie et chez l'éditeur officiel
[img]
Affichage préliminaire
Libre accès au plein texte de ce document
Version officielle de l'éditeur
Conditions d'utilisation: Creative Commons: Attribution (CC BY)
Télécharger (7MB)
Afficher le résumé
Cacher le résumé

Abstract

This paper introduces a model-based continuous commissioning (MBCCx) methodology specifically designed for the identification of control-related performance gaps within heating, ventilation and air conditioning (HVAC) systems equipped with ground-source heat pumps (GSHPs). While conventional continuous commissioning (CCx) is effective in detecting energy performance gaps, MBCCx goes further by using a system model as a reference to pinpoint operational inefficiencies and control faults arising from subsystem integration. The core of the proposed methodology lies in a calibrated physics-based model that represents the system performance as intended during the design phase. A key advantage is its applicability early in a building’s operational phase, when data is limited, unlike data-driven methods that rely on extensive historical datasets. This enables the identification of energy-saving opportunities before the system reaches a stable operational state. To address the limitations of prior studies that often focus solely on individual GSHP component performance, this work pioneers the application of MBCCx to whole buildings equipped with GSHPs. The proposed approach employs a detailed 3D building model and component-level HVAC modeling to predict parameters such as room temperatures, heat pump power, and ground heat exchanger temperatures under normal conditions. Significant deviations between monitored values and model predictions serve as indicators of underperforming components or control sequence anomalies. The anomaly detection accuracy is then improved by merging HVAC system and GSHP performance indicators. The methodology is demonstrated through a case study of a recently retrofitted elementary school in Québec, Canada, equipped with five standing column wells as ground heat exchangers.

Mots clés

Département: Département de génie mécanique
Département des génies civil, géologique et des mines
Organismes subventionnaires: NSERC / CRSNG, Geothermal Research Chair on the Integration of SCWs in Institutional Buildings, Hydro-Québec, Quebec - Ministry of higher education, Centre de services scolaire des Mille-îles (CSSMI), Centre de services scolaire de Montréal (CSSDM), Centres intégrés de santé et de services sociaux (CISSS), Versa Profiles, Marmott Energies, CanmetEnergy
Numéro de subvention: ALLRP 544477-19
URL de PolyPublie: https://publications.polymtl.ca/62964/
Titre de la revue: Energy and Buildings (vol. 333)
Maison d'édition: Elsevier
DOI: 10.1016/j.enbuild.2025.115492
URL officielle: https://doi.org/10.1016/j.enbuild.2025.115492
Date du dépôt: 24 févr. 2025 10:27
Dernière modification: 27 oct. 2025 09:30
Citer en APA 7: Tonellato, G., Kummert, M., Candanedo, J. A., Beaudry, G., & Pasquier, P. (2025). A model-based continuous commissioning method for an efficient integration of ground source heat pumps in the building ecosystem. Energy and Buildings, 333, 115492 (15 pages). https://doi.org/10.1016/j.enbuild.2025.115492