<  Retour au portail Polytechnique Montréal

Manufacturing process affects coagulation kinetics of Ortho-R, an injectable chitosan–platelet-rich plasma biomaterial for tissue repair

Anik Chevrier et Marc Lavertu

Article de revue (2024)

Document en libre accès dans PolyPublie et chez l'éditeur officiel
[img]
Affichage préliminaire
Libre accès au plein texte de ce document
Version officielle de l'éditeur
Conditions d'utilisation: Creative Commons: Attribution (CC BY)
Télécharger (8MB)
Afficher le résumé
Cacher le résumé

Abstract

Ortho-R (ChitogenX Inc., Kirkland, QC, Canada) is an injectable combination drug–biologic product that is used as an adjunct to augment the standard of care for the surgical repair of soft tissues. The drug product comprises lyophilized chitosan, trehalose and calcium chloride, and it is dissolved in platelet-rich plasma (PRP), a blood-derived biologic, prior to injection at the surgical site where it will coagulate. The first step of the Ortho-R manufacturing process involves dissolving the chitosan in hydrochloric acid. The purpose of this study was to investigate the effect of increasing the amount of acid used to dissolve the chitosan on final drug product performance, more specifically, on the chitosan–PRP coagulation kinetics. Chitosans were solubilized in hydrochloric acid, with concentrations adjusted to obtain between 60% and 95% protonation of the chitosan amino groups. Freeze-dried Ortho-R was solubilized with PRP, and coagulation was assessed using thromboelastography (TEG). The clotted mixtures were observed with histology. Clot reaction time (TEG R) increased and clot maximal amplitude (TEG MA) decreased with protonation levels as pH decreased. Chitosan distribution was homogeneous in chitosan–PRP clots at the lowest protonation levels, but it accumulated toward the surface of the clots at the highest protonation levels as pH decreased. These changes in coagulation kinetics, clot strength and chitosan distribution induced by high protonation of the chitosan amino groups were partially reversed by adding sodium hydroxide to the dissolved chitosan component in order to decrease pH. Careful control of manufacturing processes is critical, and it is important to consider the impact of each manufacturing step on product performance.

Mots clés

Département: Département de génie chimique
Institut de génie biomédical
Organismes subventionnaires: Chitogen X Inc., NSERC / CRSNG - Alliance Program
Numéro de subvention: 051712, 3101621
URL de PolyPublie: https://publications.polymtl.ca/59439/
Titre de la revue: Bioengineering (vol. 11, no 9)
Maison d'édition: Multidisciplinary Digital Publishing Institute
DOI: 10.3390/bioengineering11090929
URL officielle: https://doi.org/10.3390/bioengineering11090929
Date du dépôt: 25 oct. 2024 15:42
Dernière modification: 29 oct. 2024 21:02
Citer en APA 7: Chevrier, A., & Lavertu, M. (2024). Manufacturing process affects coagulation kinetics of Ortho-R, an injectable chitosan–platelet-rich plasma biomaterial for tissue repair. Bioengineering, 11(9), 929 (10 pages). https://doi.org/10.3390/bioengineering11090929

Statistiques

Total des téléchargements à partir de PolyPublie

Téléchargements par année

Provenance des téléchargements

Dimensions

Actions réservées au personnel

Afficher document Afficher document