Abstract

Background

Recent studies showed that finite element model (FEM) combined to CAD/CAM improves the design of braces for the conservative treatment of adolescent idiopathic scoliosis (AIS), using 2D measurements from in-brace radiographs. We aim to assess the immediate effectiveness on curve correction in all three planes of braces designed using CAD/CAM and numerical simulation compared to braces designed with CAD/CAM only.

Methods

SRS standardized criteria for bracing were followed to recruit 48 AIS patients who were randomized into two groups. For both groups, 3D reconstructions of the spine and patient's torso, respectively built from bi-planar radiographs and surface topography, were obtained and braces were designed using the CAD/CAM approach. For the test group, 3D reconstructions of the spine and patient's torso were additionally used to generate a personalized FEM to simulate and iteratively improve the brace design with the objective of curve correction maximization in three planes and brace material minimization.

Results

For the control group (CtrlBraces), average Cobb angle prior to bracing was 29° (thoracic, T) and 25° (lumbar, L) with the planes of maximal curvature (PMC) respectively oriented at 63° and 57° on average with respect to the sagittal plane. Average apical axial rotation prior to bracing was 7° (T) and 9° (L). For the test group (FEMBraces), initial Cobb angles were 33° (T) and 28° (L) with the PMC at 68° (T) and 56° (L) and average apical axial rotation prior to bracing at 9° (T and L). On average, FEMBraces were 50% thinner and had 20% less covering surface than CtrlBraces while reducing T and L curves by 47 and 48%, respectively, compared to 25 and 26% for CtrlBraces. FEMBraces corrected apical axial rotation by 46% compared to 30% for CtrlBraces.

Conclusion

The combination of numerical simulation and CAD/CAM approach allowed designing more efficient braces in all three planes, with the advantages of being lighter than standard CAD/CAM braces. Bracing in AIS may be improved in 3D by the use of this simulation platform. This study is ongoing to recruit more cases and to analyze the long-term effect of bracing.

Mots clés

Computer-aided design/computer-aided manufacturing; Scoliosis; Thoraco-lumbo-sacral orthosis; Finite element model (FEM); RCT

Sujet(s): 2100 Génie mécanique > 2100 Génie mécanique
9000 Sciences de la santé > 9000 Sciences de la santé
Département: Département de génie mécanique
Organismes subventionnaires: CRSNG/NSERC, Canadian Institutes of Health Research
Numéro de subvention: RGPIN 239148-11, MOP-119455
URL de PolyPublie: https://publications.polymtl.ca/3241/
Titre de la revue: Scoliosis and Spinal Disorders (vol. 12, no 1)
Maison d'édition: BioMed Central
DOI: 10.1186/s13013-017-0128-9
URL officielle: https://doi.org/10.1186/s13013-017-0128-9
Date du dépôt: 29 août 2018 13:49
Dernière modification: 28 sept. 2024 18:27
Citer en APA 7: Cobetto, N., Aubin, C.-É., Parent, S., Barchi, S., Turgeon, I., & Labelle, H. (2017). 3D correction of AIS in braces designed using CAD/CAM and FEM: a randomized controlled trial. Scoliosis and Spinal Disorders, 12(1). https://doi.org/10.1186/s13013-017-0128-9

Statistiques

Total des téléchargements à partir de PolyPublie

Téléchargements par année

Provenance des téléchargements

Dimensions

Actions réservées au personnel

Afficher document Afficher document