Amedeo Ceglia, François Bailly, Pierre Puchaud, Lama Séoud et Mickaël Begon
Article de revue (2026)
Un lien externe est disponible pour ce documentAbstract
Objective: Estimating personalized muscle forces through musculoskeletal modeling is valuable for assessing patient status and monitoring clinical progress. However, this process involves numerous model parameters that are difficult to measure. Upper-limb applications are particularly limited due to the complexity of the system and the long computation times required for model calibration. This study proposes a rapid (<5 min) calibration method for upper-limb musculoskeletal models. Methods: We calibrated maximal isometric force and optimal muscle length for 38 muscles across 10 degrees of freedom by matching muscle-generated moments with dynamically consistent joint moments. The method leverages experimental data including bony landmark trajectories from markerless motion capture, external forces, and electromyography (EMG). Results: Joint moment estimation and calibration were completed together in less than five minutes. During hand-cycling, the calibrated model reduced EMG tracking error compared to the uncalibrated model (5.58±0.92% vs. 6.30±1.28%). Reliance on non-physiological residual moments was also lowered (12.68 vs. 23.61% of peak moment for calibrated vs. uncalibrated models, respectively). Conclusion: The proposed method enables rapid calibration of upper-limb muscle parameters, improving accuracy in muscle force estimation and reducing dependence on residual moments. Significance: This approach provides a fast and reliable framework for upper-limb musculoskeletal calibration, facilitating more accurate and clinically applicable muscle force estimation.
| Département: | Département de génie informatique et génie logiciel |
|---|---|
| URL de PolyPublie: | https://publications.polymtl.ca/73467/ |
| Titre de la revue: | IEEE Transactions on Biomedical Engineering |
| Maison d'édition: | Institute of Electrical and Electronics Engineers |
| DOI: | 10.1109/tbme.2026.3668071 |
| URL officielle: | https://doi.org/10.1109/tbme.2026.3668071 |
| Date du dépôt: | 01 avr. 2026 16:11 |
| Dernière modification: | 25 août 2026 16:13 |
| Citer en APA 7: | Ceglia, A., Bailly, F., Puchaud, P., Séoud, L., & Begon, M. (2026). Fast Muscle-parameter Calibration using EMG and Markerless Kinematics for Neuromusculoskeletal Modeling: Application to Hand-cycling. IEEE Transactions on Biomedical Engineering, 8 pages. https://doi.org/10.1109/tbme.2026.3668071 |
|---|---|
Statistiques
Dimensions